Back to Home
LMA-TR-300-E10 Linear-Motor Stage

LMA series shown; travel and encoder options vary by model.

View full-size image

Motorized Stages

LMA-TR-300-E10 Linear-Motor Stage

  • Travel range: 300 mm
  • Repositioning accuracy: ≤±3 µm
  • Horizontal load capacity: 30 kg
  • Table size: 200×242 mm
View quote list
LMA Series Linear Motor Stages

Specifications

Mechanical

Travel range (mm)300
Table size (mm)200×242
Overall height (mm)88
Transmission mechanismIronless linear motor, direct drive (no lead screw)
Guide mechanismImported SP-grade linear ball-slide guide rails
Body material and finishAluminum alloy, black anodized
Weight (kg)32
MountingHorizontal or inverted only; not rated for vertical use

Accuracy

FeedbackRenishaw RGH20-220 steel-tape linear scale, closed loop
Closed-loop resolution (µm)1.0
Max speed (mm/s)2000 (no load)
Single-direction positioning accuracy (µm)≤6
Repositioning accuracy (µm)≤±3
Backlash (µm)≤2
Dynamic straightness (µm/200 mm)≤10
Dynamic parallelism (µm/200 mm)≤10
Yaw (arcsec)≤25
Pitch (arcsec)≤35

Motor & electrical

Motor pole pitch (mm)30
Peak thrust (N)275
Continuous thrust (N)85
Peak current (A)5
Continuous current (A)1.5
Drive amplifierCopley XSJ-230-10 (ordered separately)
ControllerTMC-USB motion controller

Sensors & connection

Connector3-pin D-sub (stage) and 15-pin D-sub (scale)
Limit sensors (built-in)2×PM-L25 (SUNX, Japan)
Deceleration sensors (built-in)2×PM-L25 (SUNX, Japan)
Sensor supply voltageDC5~24V±10%
Sensor outputNPN open-collector output DC5~24V 50mA or less
Sensor output logicOutput transistor ON when the beam is blocked

Load capacity

Horizontal load capacity (kg)30
Inverted load capacity (kg)15

Construction details

  • Guidance assembly: Imported SP-grade linear ball-slide guide rails.
  • Drive assembly: Ironless linear motor, direct drive (no lead screw).

Product comparison

Compare with Thorlabs DDS300/M

LMA-TR-300-E10 and Thorlabs DDS300/M offer options for high-speed closed-loop linear positioning. Compare the listed dimensions and interfaces for your setup.

Reference configuration: Direct drive; no lead screw with high-rigidity recirculating precision linear bearings; Brushless DC linear servo motor.

Published specifications for LMA-TR-300-E10 and Thorlabs DDS300/M
FeatureAvailable from PrecisometerLMA-TR-300-E10Comparison referenceThorlabs DDS300/M
Translation axesOne linear axisOne linear axis
Travel range300 mm300 mm
Guide mechanismImported SP-grade linear ball-slide guide railsHigh-rigidity recirculating precision linear bearings
Transmission mechanismIronless linear motor, direct drive (no lead screw)Direct drive; no lead screw
Motor packageIronless linear motor, direct drive (no lead screw)Brushless DC linear servo motor
Position feedbackRenishaw RGH20-220 steel-tape linear scale, closed loopLinear optical encoder, 50 nm resolution
Moving platform / mounting200×242 mm; compare exact model drawing for tapped-hole patternCompare reference mechanical drawing; matching platform size and hole pattern not established
Maximum speed2000 (no load) mm/s; published condition applies400 mm/s; acceleration/tuning depend on load
Horizontal load capacity30 kg10 kg maximum horizontal; not suitable for vertical motion
Published repeat-positioning measureRepositioning accuracy (direction not stated): ≤±3 µmBidirectional repeatability: ±0.25 µm
Published positioning-accuracy measureSingle-direction positioning accuracy: ≤6 µmAbsolute on-axis accuracy: ±7.5 µm
Backlash≤2 µmN/A; no lead screw
Position-feedback resolution1.0 µmEncoder resolution: 50 nm; distinct from minimum movement and accuracy
Controller / driver requirementsTMC-USB motion controller; Copley XSJ-230-10 (ordered separately); electrical compatibility with Thorlabs controllers is not establishedController sold separately: BBD30x, or UMCx with PAA712 adapter; default tuning is for 2 kg and may need adjustment

Similar application. Check the interfaces for your setup.

Both specify 300 mm travel on one linear axis. Both use direct linear motors with closed-loop position feedback, but their load, speed, feedback resolution and positioning specifications differ substantially. Published repositioning accuracy, unidirectional/bidirectional repeatability, encoder resolution, theoretical microstep size and absolute/calibrated accuracy describe different tests and must not be treated as equal performance. No drop-in mechanical, cable, controller or software compatibility is claimed. The Thorlabs DDS reference is not suitable for vertical motion and its platform can move freely when unpowered. This comparison covers the listed features and does not establish interchangeability or identical performance.

Comparison references: LMA-TR-300-E10 catalogue specifications and Thorlabs DDS300/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.

All Thorlabs part-number comparisons →