Motorized Stages
LMA-TR-100-G10 Linear-Motor Stage
- Travel range: 100 mm
- Repositioning accuracy: ≤±3 µm
- Horizontal load capacity: 30 kg
- Table size: 200×242 mm
Specifications
Mechanical
| Travel range (mm) | 100 |
|---|---|
| Table size (mm) | 200×242 |
| Overall height (mm) | 88 |
| Transmission mechanism | Ironless linear motor, direct drive (no lead screw) |
| Guide mechanism | Imported SP-grade linear ball-slide guide rails |
| Body material and finish | Aluminum alloy, black anodized |
| Mounting | Horizontal or inverted only; not rated for vertical use |
Accuracy
| Feedback | Glass linear scale, closed loop |
|---|---|
| Closed-loop resolution (µm) | 1.0 |
| Max speed (mm/s) | 2000 (no load) |
| Single-direction positioning accuracy (µm) | ≤6 |
| Repositioning accuracy (µm) | ≤±3 |
| Backlash (µm) | ≤2 |
| Dynamic straightness (µm/200 mm) | ≤10 |
| Dynamic parallelism (µm/200 mm) | ≤10 |
Motor & electrical
| Motor pole pitch (mm) | 30 |
|---|---|
| Peak thrust (N) | 275 |
| Continuous thrust (N) | 85 |
| Peak current (A) | 5 |
| Continuous current (A) | 1.5 |
| Drive amplifier | Copley XSJ-230-10 (ordered separately) |
| Controller | TMC-USB motion controller |
Sensors & connection
| Connector | 3-pin D-sub (stage) and 15-pin D-sub (scale) |
|---|---|
| Limit sensors (built-in) | 2×PM-L25 (SUNX, Japan) |
| Deceleration sensors (built-in) | 2×PM-L25 (SUNX, Japan) |
| Sensor supply voltage | DC5~24V±10% |
| Sensor output | NPN open-collector output DC5~24V 50mA or less |
| Sensor output logic | Output transistor ON when the beam is blocked |
Load capacity
| Horizontal load capacity (kg) | 30 |
|---|---|
| Inverted load capacity (kg) | 15 |
Construction details
- Guidance assembly: Imported SP-grade linear ball-slide guide rails.
- Drive assembly: Ironless linear motor, direct drive (no lead screw).
Product comparison
Compare with Thorlabs DDS100/M
LMA-TR-100-G10 and Thorlabs DDS100/M offer options for high-speed closed-loop linear positioning. Compare the listed dimensions and interfaces for your setup.
Reference configuration: Direct drive; no lead screw with high-rigidity recirculating precision linear bearing; Brushless DC linear servo motor.
| Feature | Available from PrecisometerLMA-TR-100-G10 | Comparison referenceThorlabs DDS100/M |
|---|---|---|
| Translation axes | One linear axis | One linear axis |
| Travel range | 100 mm | 100 mm |
| Guide mechanism | Imported SP-grade linear ball-slide guide rails | High-rigidity recirculating precision linear bearing |
| Transmission mechanism | Ironless linear motor, direct drive (no lead screw) | Direct drive; no lead screw |
| Motor package | Ironless linear motor, direct drive (no lead screw) | Brushless DC linear servo motor |
| Position feedback | Glass linear scale, closed loop | Linear optical encoder; 500 nm resolution |
| Moving platform / mounting | 200×242 mm; compare exact model drawing for tapped-hole pattern | Compare reference mechanical drawing; matching platform size and hole pattern not established |
| Maximum speed | 2000 (no load) mm/s; published condition applies | 500 mm/s |
| Horizontal load capacity | 30 kg | 0.9 kg maximum horizontal; not suitable for vertical motion |
| Published repeat-positioning measure | Repositioning accuracy (direction not stated): ≤±3 µm | Bidirectional repeatability: ±1.5 µm |
| Published positioning-accuracy measure | Single-direction positioning accuracy: ≤6 µm | Absolute on-axis accuracy: ±6.5 µm |
| Backlash | ≤2 µm | N/A; no lead screw |
| Position-feedback resolution | 1.0 µm | Encoder resolution: 500 nm; distinct from the 5.0 µm minimum incremental movement |
| Controller / driver requirements | TMC-USB motion controller; Copley XSJ-230-10 (ordered separately); electrical compatibility with Thorlabs controllers is not established | KBD101 brushless DC controller and suitable power supply sold separately; not a motor/drive package shared with Precisometer |
Similar application. Check the interfaces for your setup.
Both specify 100 mm travel on one linear axis. Both use direct linear motors with closed-loop position feedback, but their load, speed, feedback resolution and positioning specifications differ substantially. Published repositioning accuracy, unidirectional/bidirectional repeatability, encoder resolution, theoretical microstep size and absolute/calibrated accuracy describe different tests and must not be treated as equal performance. No drop-in mechanical, cable, controller or software compatibility is claimed. The Thorlabs DDS reference is not suitable for vertical motion and its platform can move freely when unpowered. This comparison covers the listed features and does not establish interchangeability or identical performance.
Comparison references: LMA-TR-100-G10 catalogue specifications and Thorlabs DDS100/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.