Back to Home
DNXP-A Motorized Driver For NXP Flexure Platform

Manufacturer sheet labels DNXP-A alongside NXP-MR01, DNXP-M and DNXP-A. Refer to the labelled item; this is a shared dimensional sheet.

View full-size image

Motorized Stages

DNXP-A Motorized Driver For NXP Flexure Platform

  • Drive type: Motorized, two-phase stepper
  • Driver travel: 8 mm
  • Effective NXP travel: 4 mm
  • Step / half-step resolution: 1.25 µm / 0.625 µm
View quote list
Fiber Alignment Stages

Specifications

Drive typeMotorized, two-phase stepper
Driver travel8 mm
Effective NXP travel4 mm
Step / half-step resolution1.25 µm / 0.625 µm
Bidirectional repeatability5 µm
Motor35 mm stepper; 1.8° step angle
Limit switchBuilt in
CompatibilityNXP-3M and NXP-6M platforms; one driver per axis

Product comparison

Compare with Thorlabs DRV208

DNXP-A and Thorlabs DRV208 offer options for motorized actuation of configurable flexure stages. Compare the listed dimensions and interfaces for your setup.

Reference configuration: 8 mm modular stepper actuator for Thorlabs NanoMax stages; controller excluded.

Published specifications for DNXP-A and Thorlabs DRV208
FeatureAvailable from PrecisometerDNXP-AComparison referenceThorlabs DRV208
Actuator travel (mm)8 mm8
Travel when installed on intended flexure stage4 mm4 mm on NanoMax translation axes
Bidirectional repeatability5 µm5.0 µm quoted for NanoMax stage/DRV208 configuration
Motor driveMotorized, two-phase stepperStepper motor actuator
Controller and installationNXP-3M and NXP-6M platforms; one driver per axis; matching controller must be specifiedThorlabs NanoMax modular actuator interface; UMC-series controller sold separately

Similar application. Check the interfaces for your setup.

Both are modular motorized actuators for a flexure platform, and their full actuator travel differs from the installed stage travel. The quoted Thorlabs repeatability is for its NanoMax configuration; it is not an independently interchangeable NXP actuator. Mounting, coupling, preload, current and homing/limit interfaces require separate verification. DNXP-A requires its matched NXP controller configuration; the exact controller/pinout is not specified on this scalar table. DRV208 requires a compatible Thorlabs controller, such as UMC1 (XA software), sold separately. The actuator/stage interfaces and controller wiring are not cross-brand interchangeable. This comparison covers the listed features and does not establish interchangeability or identical performance.

Comparison references: DNXP-A catalogue specifications and Thorlabs DRV208 published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.

All Thorlabs part-number comparisons →