AKV6A-40C Aluminum Alloy High Precision Vertical Stage
- Travel range( mm ): 6
- Sensitivity: ≤2 µm
- Stage surface size: 40×40 mm
- Stage surface height range( mm ): 54.5-60.5
Specifications
| Stage surface size(mm) | 40×40 |
|---|---|
| Travel range( mm ) | 6 |
| Stage surface height range( mm ) | 54.5-60.5 |
| Guide mechanism | linear-slider guides |
| Lifting mechanism | Lever lift |
| Drive type | Micrometer |
| Drive location | Central and horizontal |
| Main body material and surface | Black anodized aluminum alloy |
| Weight(Kg) | 0.25 |
| Sensitivity(µm) | ≤2 |
| Minimum reading of micrometer(mm) | 0.01 |
| Height changes by tuning a round of microme-ter(mm) | 0.5 |
| Central load capacity(Kg) | ≤2 |
| Static parallelism(um) | ≤100 |
Construction details
- Drive assembly: Micrometer.
Downloads
Product comparison
Compare with Thorlabs MVS05/M
AKV6A-40C and Thorlabs MVS05/M offer options for manual vertical positioning of optical assemblies. Compare the listed dimensions and interfaces for your setup.
Reference configuration: manual micrometer-driven vertical stages.
| Feature | Available from PrecisometerAKV6A-40C | Comparison referenceThorlabs MVS05/M |
|---|---|---|
| Vertical travel | 6 mm | 13.0 mm |
| Working platform height | 54.5-60.5 mm | 63.0–76.0 mm |
| Guidance | linear-slider guides | Crossed-roller bearings |
| Actuation | Micrometer | Micrometer |
| Published centered load | ≤2 kg | 2 kg within plate area |
| Body | Black anodized aluminum alloy | Black-anodized aluminum |
Similar application. Check the interfaces for your setup.
Same vertical positioning task. Travel, working height, guide construction and load rating must be checked for this exact model; no shared footprint or interchangeable mounting is established. MVS05/M is the current reference, replacing the discontinued MVS005/M. This comparison covers the listed features and does not establish interchangeability or identical performance.
Comparison references: AKV6A-40C catalogue specifications and Thorlabs MVS05/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.