Back to Home
PA800-Z Motorized Vertical Stage

Zolix · Motorized Stages

PA800-Z Motorized Vertical Stage

Motorized vertical stage with 800 mm travel and a 200×200 mm table. Transmission: precision ball screw φ25×5; guide: linear-slider guides. Repositioning accuracy ≤±5 µm; max speed 50 mm/s. Vertical load capacity 30 kg (centred); weight 35 kg.

Travel range
800 mm
Repositioning accuracy
≤±5 µm
Table size
200×200 mm
Transmission mechanism
Precision ball screw φ25×5
View quote list
PAxx-Z Series Precise Motorized Vertical-Motion Stages

Specifications

Mechanical

Travel range (mm)800
Table size (mm)200×200
Transmission mechanismPrecision ball screw φ25×5
Guide mechanismLinear-slider guides
Body material and finishBlack anodized aluminum alloy
Weight (kg)35
Shaft coupling, OD-bore-bore (mm)32-8-12

Accuracy

Resolution, full step (µm)25
Resolution, 20× microstep (µm)1.25
Max speed (mm/s)50
Repositioning accuracy (µm)≤±5
Static clearance (µm)≤3
Backlash (µm)≤5
Static parallelism (mm)≤0.12
Dynamic straightness (µm/100 mm)≤15
Dynamic parallelism (µm/100 mm)≤15

Motor & electrical

Motor and step angle (°)Two-phase 57 stepping motor, 1.8
Motor modelShinano, SST59D5301-SD
Motor current (A)3.0
Motor holding torque (N·m)1.57
Stepper driver (optional)Moons, SR4

Sensors & connection

ConnectorDB9 (pin)
Cable typeHigh flexibility cable (Helukabel, Germany)
Cable length (m)0.2
Limit sensors (built-in)2×PM-L25 (SUNX, Japan)
Origin sensor (built-in)1×PM-L25 (SUNX, Japan)
Sensor supply voltageDC5~24V±10%
Sensor current consumption (mA)<60 (total)
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicPosition limit sensor: output ON when sensor is blocked; Origin-point sensor: output OFF when sensor is blocked;

Load capacity

Vertical load capacity, centred (kg)30

Compatible controllers

For the two-phase 57 stepping motor this stage uses.