Power stability, linewidth, beam quality
UV-DP-313-A313 nm UV CW laser
313 nmUV-DP-313-A is a 313 nm CW laser. Used for flow cytometry, dna sequencing, optical instrument, medical imaging. Laser. Key specifications: output / average power 1~500 mW, operating mode CW, power stability (rms, 4 hours±3℃) <3%, <2%, <1% / <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
UV-DP-313-A
17 specification rows
| Wavelength | 313 nm |
|---|---|
| Output / average power | 1~500 mW |
| Beam / notes | Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours±3℃) | <3%, <2%, <1% / <2%, <1%, <0.5% |
| Transverse mode | Near TEM00 |
| Beam divergence, full angle (mrad) | <3.0 |
| Warm-up time (minutes) | <10 |
| Cooled method | Air Cooled / WCH-580 (Water Cooled) |
| Operating temperature (℃) | 10-35 |
| Power supply (100-240VAC) | PSU-DP-A / / |
| Operating voltage (VDC) | / / 12V/ 25A |
| Expected lifetime (hours) | >10000 |
| Output power (mW) | 1-500 |
| Beam diameter at the aperture (1/e2, mm) | <3.0 |
| Polarization ratio | >50:1(>100:1 optional) Vertical (Horizontal optional) |
| Beam height from base plate (mm) | 50 |
| Modulation option | / |
Applications
Typical uses for lasers of this wavelength and type in this catalogue.
- Flow cytometry
- DNA sequencing
- Optical instrument
- Medical imaging
- Laser medical treatment