Back to Home

Power stability, linewidth, beam quality

PGL-VI-473473 nm blue CW laser

473 nm

PGL-VI-473 is a 473 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Features: Laser module. Key specifications: output / average power 1~20 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-VI-473

16 specification rows

Wavelength473 nm
Output / average power1~20 mW
Beam / notesFeatures: Laser module
Operating modeCW
Transverse modeTEM00
Beam divergence, full angle (mrad)<1.5
Expected lifetime (hours)10000
Warranty (years)1
Operating voltage(internal PCB)3VDC
ConnectionCable with flying leads
Operating temperature10°C to 35°C
Storage temperature-20°C to 80°C
Humidity<90%, non-condensing
Dimensions of PGL-VI-473Φ20×100mm2
Dimensions of PGL-VI-1-473Φ15×65mm2
Dimensions of externalcontrol 750hz frequency)
FeaturesLaser module

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

PGL-VI-473: 473 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

PGL-VI-473: 473 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

PGL-VI-473: 473 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Spectrum analysis

PGL-VI-473: 473 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect PGL-VI-473 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: 10°C to 35°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Beam divergence, full angle (mrad): <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of PGL-VI-473: Φ20×100mm2 · Dimensions of PGL-VI-1-473: Φ15×65mm2
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-VI-473

What cooling does the PGL-VI-473 require?

Operating temperature: 10°C to 35°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-VI-473 deliver?

Transverse mode: TEM00 · Beam divergence, full angle (mrad): <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-VI-473 mounted?

Dimensions of PGL-VI-473: Φ20×100mm2 · Dimensions of PGL-VI-1-473: Φ15×65mm2. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-VI-473 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-VI-473 (current)MSL-S-473-DMSL-U-473
Wavelength473 nm473 nm473 nm
Optical power / pulse energy1~20 mW1~30 mW1~100 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00