Back to Home

Fiber output, PM options, seed formats

PGL-V-H-FP-405405 nm violet fiber laser

405 nm

PGL-V-H-FP-405 is a 405 nm Fiber laser. Used for medical imaging, flow cytometry, dna sequencing, measurement. Features: SM Fiber coupled. Key specifications: output / average power 1~200 mW, power stability <1%, operating mode CW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-V-H-FP-405

15 specification rows

Wavelength405 nm
Output / average power1~200 mW
Power stability<1%
Beam / notesFeatures: SM Fiber coupled
Operating modeCW
Transverse modeNear TEM00 / Multimode
Beam divergence, full angle (mrad)<0.5 / <3×0.5
Warm-up timeminutes / <10
Expected lifetime (hours)10000
Operating voltage(PSU-V-OEM)100-240VAC
Connection9 pin connector
Operating temperature-10°C to 50°C
Storage temperature-20°C to 80°C
Humidity< 90%, non-condensing
Dimensions of laser head92(L)×40(W)×40(H)mm3
FeaturesSM Fiber coupled

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Medical imaging

PGL-V-H-FP-405: 405 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

PGL-V-H-FP-405: 405 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

PGL-V-H-FP-405: 405 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Measurement

PGL-V-H-FP-405: Measurement benefits from a stable, focusable source. 405 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Near TEM00 / Multimode) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect PGL-V-H-FP-405 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: -10°C to 50°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 / Multimode · Beam divergence, full angle (mrad): <0.5 / <3×0.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of laser head: 92(L)×40(W)×40(H)mm3
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-V-H-FP-405

What cooling does the PGL-V-H-FP-405 require?

Operating temperature: -10°C to 50°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-V-H-FP-405 deliver?

Transverse mode: Near TEM00 / Multimode · Beam divergence, full angle (mrad): <0.5 / <3×0.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-V-H-FP-405 mounted?

Dimensions of laser head: 92(L)×40(W)×40(H)mm3. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-V-H-FP-405 with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-V-H-FP-405 (current)MDL-III-405-SMOEM-I-405
Wavelength405 nm405 nm405 nm
Optical power / pulse energy1~200 mW1~30 mW120 mW
Operating mode / pulse widthCWCWCW
Beam qualityNear TEM00 / MultimodeMultimodeConfirm for this model