Back to Home

Power stability, linewidth, beam quality

PGL/MDL-L series405 nm violet CW laser

405 nm

PGL/MDL-L series is a 405 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Features: Line beam, focus adjustable. Key specifications: output / average power 1~1000 mW, power stability <0.5%, operating mode CW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL/MDL-L series

15 specification rows

Wavelength405 nm
Output / average power1~1000 mW
Power stability<0.5%
Beam / notesFeatures: Line beam, focus adjustable
Operating modeCW
Transverse modeNear TEM00
Warm-up timeminutes / <10
Expected lifetime (hours)10000
Warranty (years)1
Operating voltage(PSU-II-OEM)7V / (TTL30kHz or Analog 0-5V,optional)
ConnectionCable with flying leads
Operating temperature-10°C to 50°C
Storage temperature-20°C to 80°C
Humidity< 90%, non-condensing
Dimensions of laser head77(L)×30(W)×30(H)mm3
FeaturesLine beam, focus adjustable

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

PGL/MDL-L series: 405 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

PGL/MDL-L series: 405 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

PGL/MDL-L series: 405 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

PGL/MDL-L series: 405 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (Near TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect PGL/MDL-L series to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: -10°C to 50°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of laser head: 77(L)×30(W)×30(H)mm3
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL/MDL-L series

What cooling does the PGL/MDL-L series require?

Operating temperature: -10°C to 50°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL/MDL-L series deliver?

Transverse mode: Near TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL/MDL-L series mounted?

Dimensions of laser head: 77(L)×30(W)×30(H)mm3. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL/MDL-L series with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL/MDL-L series (current)MSL-T-405MDL-C-405
Wavelength405 nm405 nm405 nm
Optical power / pulse energy1~1000 mW1~80 mW1~50 mW
Operating mode / pulse widthCWCWCW
Beam qualityNear TEM00<1Multimode