Power stability, linewidth, beam quality

MSL-T-405405 nm violet narrow-linewidth CW laser

405 nm

MSL-T-405 is a 405 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Key specifications: output / average power 1~80 mW, spectral linewidth <0.000005 nm (<10 MHz) Coherent length >30m, optical noise <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-T-405

19 specification rows

Wavelength405 nm
Output / average power1~80 mW
Spectral linewidth<0.000005 nm (<10 MHz) Coherent length >30m
Optical noise<0.5%
Operating modeCW
Longitudinal modeSingle
Power stability (rms, 4 hours±3℃)<1%, <0.5%
Beam divergence, full angle (mrad)<1
Beam diameter at the aperture (1/e2,mm)<2
M2<1.2
Polarization ratio>100:1,Vertical(Horizontal optional)
Cooled methodWater cooled
Operating temperature (℃)15-35
Power supply (220/110VAC)RAD1PS
Expected lifetime (hours)>10000
Output power (mW)1-80
Coherent length (m)>30
<1.2
Noise of amplitude (rms,20Hz-20MHz)<0.5%
Beam height from base plate (mm)51

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MSL-T-405: 405 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MSL-T-405: 405 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MSL-T-405: 405 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

MSL-T-405: 405 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<1) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect MSL-T-405 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <1 · Beam diameter at the aperture (1/e2,mm): <2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MSL-T-405

What cooling does the MSL-T-405 require?

Cooled method: Water cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MSL-T-405 deliver?

Beam divergence, full angle (mrad): <1 · Beam diameter at the aperture (1/e2,mm): <2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-T-405 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-T-405 (current)MDL-C-405MDL-E-405
Wavelength405 nm405 nm405 nm
Optical power / pulse energy1~80 mW1~50 mW1~50 mW
Operating mode / pulse widthCWCWCW
Beam quality<1MultimodeMultimode