Back to Home

Power stability, linewidth, beam quality

PGL-FP-905905 nm near-infrared CW laser

905 nm

PGL-FP-905 is a 905 nm CW laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. Laser. Key specifications: output / average power 1~70 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-FP-905

2 specification rows

Wavelength905 nm
Output / average power1~70 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 11 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~60 mW
  • Output / average power: 1~70 mW
  • Output / average power: 1~400 mW
  • Operating mode: CW
  • Operating mode: Modulation (Pulse)

Beam-quality tolerance context

Nearby series records state M²: <1.1, Beam divergence, full angle (mrad): <1.5, Beam divergence, full angle (mrad): <1.0, and Beam divergence, full angle (mrad): <3.0. These are series context, not guaranteed values for PGL-FP-905; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

PGL-FP-905: 905 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

PGL-FP-905: 905 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

PGL-FP-905: 905 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Measurement

PGL-FP-905: Measurement benefits from a stable, focusable source. 905 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-FP-905 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-FP-905 (current)TEM-LN-905MLL-III-905L
Wavelength905 nm905 nm905 nm
Optical power / pulse energy1~70 mW1~60 mW1~70 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelTEM00Near TEM00