OEM-BD-455 is a 454 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Laser. Key specifications: output / average power 40~50 W, operating mode CW, beam divergence, full angle (mrad) ~1.2. View specifications, datasheet and enquiry options from Precisometer.
DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL/ Analog optional
Expected lifetime (hours)
>10000
Wavelength (nm)
455±5
Output power (W)
40
Beam diameter at the aperture (mm)
8.5*7
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
OEM-BD-455: 454 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
OEM-BD-455: 454 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
OEM-BD-455: 454 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Spectrum analysis
OEM-BD-455: 454 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (~1.2) also controls focusing and collection geometry.
System integration
Integration and compatibility
Use these checks to connect OEM-BD-455 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Air cooled · Operating temperature (℃): 0-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): ~1.2 · Beam diameter at the aperture (mm): 8.5*7
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for OEM-BD-455
What cooling does the OEM-BD-455 require?+
Cooled method: Air cooled · Operating temperature (℃): 0-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the OEM-BD-455 deliver?+
Beam divergence, full angle (mrad): ~1.2 · Beam diameter at the aperture (mm): 8.5*7. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare OEM-BD-455 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.