Back to Home

Power stability, linewidth, beam quality

MXL-515514.5 nm green CW laser

514.5 nm

MXL-515 is a 514.5 nm CW laser. Used for collimation, laser medical treatment, flow cytometry, dna sequencing. Fiber High Stability Green Laser. Key specifications: output / average power 1~500 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MXL-515

2 specification rows

Wavelength514.5 nm
Output / average power1~500 mW
Beam / notesFiber High Stability Green Laser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~20 mW
  • Output / average power: 1~400 mW
  • Output / average power: 1~90 mW
  • Operating mode: CW
  • Spectral linewidth: 0.1 nm, (0.06 optional)

Beam-quality tolerance context

Nearby series records state M²: <1.5, M²: <1.2, M²: 1.1, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for MXL-515; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser source and internal thermal control
  2. Step 2Configured fiber launch or integrated pigtail
  3. Step 3Mode- and connector-matched patch lead
  4. Step 4Collimator, isolator or experiment input

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Collimation

MXL-515: Collimation benefits from a stable, focusable source. 514.5 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Laser medical treatment

MXL-515: 514.5 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Flow cytometry

MXL-515: 514.5 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

MXL-515: 514.5 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MXL-515 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMXL-515 (current)FC-D-514.5MDL-C-514.5
Wavelength514.5 nm514.5 nm514.5 nm
Optical power / pulse energy1~500 mW1~20 mW1~20 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelConfirm for this model<1.5