MSL-W-588 is a 588 nm Single-Frequency laser. Used for dna sequencing, flow cytometry, cell sorting, optical instruments. M²: <1.5. Key specifications: output / average power 200~500 mW, spectral linewidth <0.00001 nm, optical noise <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Pointing stability (urad) (over 2 hours after warm-up and ±3°C)
<50
Beam height from base plate (mm)
58
Application context
Why this design is used
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
DNA sequencing
MSL-W-588: 588 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
MSL-W-588: 588 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Cell sorting
MSL-W-588: 588 nm emission determines compatible optics, coatings and detectors for Cell sorting. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.
Optical instruments
MSL-W-588: 588 nm emission determines compatible optics, coatings and detectors for Optical instruments. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect MSL-W-588 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method (Water cooled): WCH-580 · Operating temperature (°C): 20-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
M²: <1.5 · Transverse mode: TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MSL-W-588
What cooling does the MSL-W-588 require?+
Cooled method (Water cooled): WCH-580 · Operating temperature (°C): 20-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MSL-W-588 deliver?+
M²: <1.5 · Transverse mode: TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.