Back to Home

SLM, narrow linewidth, coherence

MSL-Ti-CW-785785 nm near-infrared single-frequency laser

785 nm

MSL-Ti-CW-785 is a 785 nm Single-Frequency laser. Used for dna sequencing, cell sorting, optical instrument, spectrum analysis. Linewidth <500 fm. Key specifications: output / average power 1~1200 mW, operating mode CW, power stability (rms, 4 hours±3℃) <3%, <2%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-Ti-CW-785

17 specification rows

Output / average power1~1200 mW
Beam / notesLinewidth <500 fm
Operating modeCW
Power stability (rms, 4 hours±3℃)<3%, <2%
Line width (fm)<500
Beam divergence, full angle (mrad)<4
Warm-up time (minutes)<10
Cooled methodWater Cooled
Operating temperature (℃)15-35
Power supply (100-240VAC)RAD1PS
Expected lifetime (hours)>10000
Spectral linewidth<500 fm nm
Wavelength (nm)785±1
Output power (mW)1-1200
Coherent length (m)>10
Beam diameter at the aperture (1/e2,mm)<3
Beam height from base plate (mm)82

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

DNA sequencing

MSL-Ti-CW-785: 785 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Cell sorting

MSL-Ti-CW-785: 785 nm emission determines compatible optics, coatings and detectors for Cell sorting. The catalogued beam parameter (<4) helps predict how the source will focus and propagate through the instrument.

Optical instrument

MSL-Ti-CW-785: 785 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (<4) helps predict how the source will focus and propagate through the instrument.

Spectrum analysis

MSL-Ti-CW-785: 785 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<4) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect MSL-Ti-CW-785 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <4 · Beam diameter at the aperture (1/e2,mm): <3
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MSL-Ti-CW-785

What cooling does the MSL-Ti-CW-785 require?

Cooled method: Water Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MSL-Ti-CW-785 deliver?

Beam divergence, full angle (mrad): <4 · Beam diameter at the aperture (1/e2,mm): <3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-Ti-CW-785 with the closest available models in the Single-Frequency Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-Ti-CW-785 (current)785MSL-T-785
Wavelength785 nm785 nm785 nm
Optical power / pulse energy1~1200 mW1~120 mW1~300 mW
Operating mode / pulse widthCWConfirm for this modelConfirm for this model
Beam quality<4<1.5<0.5