Back to Home

SLM, narrow linewidth, coherence

MSL-Ti-800800 nm near-infrared single-frequency laser

800 nm

MSL-Ti-800 is a 800 nm Single-Frequency laser. Used for dna sequencing, cell sorting, optical instrument, spectrum analysis. Water cooled. Key specifications: output / average power 1~200 mW, operating mode CW, line width (nm) <0.00001. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-Ti-800

9 specification rows

Wavelength800 nm
Output / average power1~200 mW
Beam / notesWater cooled
Operating modeCW
Line width (nm)<0.00001
Power stability (rms, 4 hours±3℃)<3%, <2%
Beam divergence, full angle (mrad)<1
Warm-up time (minutes)<10
Power supply (100-240VAC)PSU-H-FDA
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

DNA sequencing

MSL-Ti-800: 800 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Cell sorting

MSL-Ti-800: 800 nm emission determines compatible optics, coatings and detectors for Cell sorting. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.

Optical instrument

MSL-Ti-800: 800 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.

Spectrum analysis

MSL-Ti-800: 800 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<1) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect MSL-Ti-800 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Beam / notes: Water cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MSL-Ti-800

What cooling does the MSL-Ti-800 require?

Beam / notes: Water cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MSL-Ti-800 deliver?

Beam divergence, full angle (mrad): <1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-Ti-800 with the closest available models in the Single-Frequency Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-Ti-800 (current)800793
Wavelength800 nm800 nm793 nm
Optical power / pulse energy1~200 mW1~200 mW1~200 mW
Operating mode / pulse widthCWConfirm for this modelConfirm for this model
Beam quality<1<1.5<1.5