MSL-S-532532 nm green narrow-linewidth single-frequency laser
532 nm
MSL-S-532 is a 532 nm Single-Frequency laser. Used for dna sequencing, flow cytometry, cell sorting, optical instruments. M²: <1.2. Key specifications: output / average power 1~150 mW, spectral linewidth <1 MHz, optical noise <0.2%. View specifications, datasheet and enquiry options from Precisometer.
Engineering context for a thin Single-Frequency Lasers record
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 113 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Typical operating fields in the series
• Output / average power: 1~30 mW
• Output / average power: 1~50 mW
• Output / average power: 50~300 mW
• Operating mode: CW
• Spectral linewidth: <1 MHz
Beam-quality tolerance context
Nearby series records state M²: <1.5, M²: <1.2, Beam divergence, full angle (mrad): <1.0, and Beam divergence, full angle (mrad): <1.2. These are series context, not guaranteed values for MSL-S-532; confirm them on the order-specific datasheet.
Optical integration schematic
Step 1Laser head and temperature-stabilized base
Step 2Safety shutter and optional optical isolator
Step 3Beam steering, expansion or fiber-launch optics
Step 4Experiment input with wavelength-matched coatings
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
DNA sequencing
MSL-S-532: 532 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.2%) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
MSL-S-532: 532 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.2%) helps keep measured intensity changes attributable to the sample rather than source drift.
Cell sorting
MSL-S-532: 532 nm emission determines compatible optics, coatings and detectors for Cell sorting. The catalogued beam parameter (<1.2) helps predict how the source will focus and propagate through the instrument.
Optical instruments
MSL-S-532: 532 nm emission determines compatible optics, coatings and detectors for Optical instruments. The catalogued beam parameter (<1.2) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect MSL-S-532 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Beam parameters at the output
M²: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MSL-S-532
What beam does the MSL-S-532 deliver?+
M²: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.