MSL-R-3 55 is a 355 nm CW laser. Used for flow cytometry, dna sequencing, optical instrument, medical imaging. Key specifications: output / average power 10~100 mW, spectral linewidth <5 MHz, power stability <1%. View specifications, datasheet and enquiry options from Precisometer.
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 11 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Typical operating fields in the series
• Output / average power: 1~10 mW
• Output / average power: 10~50 mW
• Output / average power: 50~500 mW
• Operating mode: CW
• Spectral linewidth: <1 MHz
Beam-quality tolerance context
Nearby series records state M²: ~3.0, M²: <1.1, M²: <1.3, and Beam divergence, full angle (mrad): <3.0. These are series context, not guaranteed values for MSL-R-3 55; confirm them on the order-specific datasheet.
Optical integration schematic
Step 1Laser head and temperature-stabilized base
Step 2Safety shutter and optional optical isolator
Step 3Beam steering, expansion or fiber-launch optics
Step 4Experiment input with wavelength-matched coatings
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
MSL-R-3 55: 355 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
MSL-R-3 55: 355 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Optical instrument
MSL-R-3 55: 355 nm emission determines compatible optics, coatings and detectors for Optical instrument. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Medical imaging
MSL-R-3 55: 355 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MSL-R-3 55 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.