Power stability, linewidth, beam quality

MSL-FN-3 55355 nm UV narrow-linewidth CW laser

355 nm

MSL-FN-3 55 is a 355 nm CW laser. Used for flow cytometry, dna sequencing, optical instrument, medical imaging. Key specifications: output / average power 1~10 mW, spectral linewidth <1 MHz, power stability <2%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-FN-3 55

4 specification rows

Wavelength355 nm
Output / average power1~10 mW
Spectral linewidth<1 MHz
Power stability<2%
Optical noise<0.5%

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 11 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 10~100 mW
  • Output / average power: 1~10 mW
  • Output / average power: 10~50 mW
  • Operating mode: CW
  • Spectral linewidth: <5 MHz

Beam-quality tolerance context

Nearby series records state M²: ~3.0, M²: <1.1, M²: <1.3, and Beam divergence, full angle (mrad): <3.0. These are series context, not guaranteed values for MSL-FN-3 55; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MSL-FN-3 55: 355 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MSL-FN-3 55: 355 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Optical instrument

MSL-FN-3 55: 355 nm emission determines compatible optics, coatings and detectors for Optical instrument. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Medical imaging

MSL-FN-3 55: 355 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-FN-3 55 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-FN-3 55 (current)MSL-R-3 55UV-FN-355-LN
Wavelength355 nm355 nm355 nm
Optical power / pulse energy1~10 mW10~100 mW1~10 mW
Operating mode / pulse widthConfirm for this modelConfirm for this modelCW
Beam qualityConfirm for this modelConfirm for this modelTEM00