Back to Home

Power stability, linewidth, beam quality

MRL-FN-607-H607 nm orange CW laser

607 nm

MRL-FN-607-H is a 607 nm CW laser. Used for collimation, laser medical treatment, scientific experiment, optical instrument. Laser. Key specifications: output / average power 800~1800 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MRL-FN-607-H

11 specification rows

Wavelength607 nm
Output / average power800~1800 mW
Beam / notesLaser
Operating modeCW
Transverse modeTEM00
M2<1.2
Beam divergence, full angle (mrad)<1.5
Warm-up time (minutes)<5
Operating Temperature (°C)10-35
Modulation optionalDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Power supply (100-240VAC)PSU-H-FDA/PSU-H-LED/PSU-SR
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MRL-FN-607-H: Collimation benefits from a stable, focusable source. 607 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MRL-FN-607-H: 607 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiment

MRL-FN-607-H: 607 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instrument

MRL-FN-607-H: 607 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MRL-FN-607-H to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating Temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MRL-FN-607-H

What cooling does the MRL-FN-607-H require?

Operating Temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MRL-FN-607-H deliver?

Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MRL-FN-607-H with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMRL-FN-607-H (current)MSL-FN-607MSL-R-607
Wavelength607 nm607 nm607 nm
Optical power / pulse energy800~1800 mW1~200 mW200~1000 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00