Back to Home

Power stability, linewidth, beam quality

MRL-FN-607607 nm orange CW laser

607 nm

MRL-FN-607 is a 607 nm CW laser. Used for collimation, laser medical treatment, scientific experiment, optical instrument. Laser. Key specifications: output / average power 500~800 mW, operating mode CW, power stability (rms, over 4 hours) <2%, <1%, 0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MRL-FN-607

15 specification rows

Wavelength607 nm
Output / average power500~800 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, over 4 hours)<2%, <1%, 0.5%
Transverse modeTEM00
M2 factor<1.2
Beam divergence, full angle (mrad)<1.5
Warm-up time (minutes)<5
Pointing stability after warm-up (mrad)<0.05
Operating Temperature (°C)10-35
Modulation optionalDC-30kHz; TTL and Analog modulation optional
Power supply (90-264VAC)PSU-H-LED/PSU-H-FDA/PSU-SR
Expected lifetime (hours)>10000
<1.2
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MRL-FN-607: Collimation benefits from a stable, focusable source. 607 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MRL-FN-607: 607 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiment

MRL-FN-607: 607 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instrument

MRL-FN-607: 607 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MRL-FN-607 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating Temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2 factor: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MRL-FN-607

What cooling does the MRL-FN-607 require?

Operating Temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MRL-FN-607 deliver?

Transverse mode: TEM00 · M2 factor: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MRL-FN-607 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMRL-FN-607 (current)MSL-FN-607MSL-R-607
Wavelength607 nm607 nm607 nm
Optical power / pulse energy500~800 mW1~200 mW200~1000 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00