Back to Home

Power stability, linewidth, beam quality

MLL-W-473-SM473 nm blue CW laser

473 nm

MLL-W-473-SM is a 473 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Key specifications: output / average power 50~1000 mW, spectral linewidth < 0.1 nm, power stability <2%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-W-473-SM

22 specification rows

Output / average power50~1000 mW
Spectral linewidth< 0.1 nm
Power stability<2%
Optical noise<1%
Operating modeCW
Transverse modeTEM00 (single mode fiber output)
M2<1.1
Polarization (optional)>50:1 after PM fiber
Fiber connectorFC/APC
Fiber length1m
Fiber JacketPVC, Metal optional
Warm-up time (minutes)<10
Cooled methodWater cooled
Operating temperature (°C)10-30
Power supply (100-240VAC)PSU-W-LED
Expected lifetime (hours)>10000
Wavelength (nm)473±1
Output power (mW)50-1000
<1.1
Noise of amplitude (rms, 20Hz-20MHz)<1%
Fiber core diameter3.5um,0.10NA
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MLL-W-473-SM: 473 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MLL-W-473-SM: 473 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MLL-W-473-SM: 473 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

MLL-W-473-SM: 473 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (TEM00 (single mode fiber output)) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect MLL-W-473-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber connector: FC/APC · Fiber core diameter: 3.5um,0.10NA
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Water cooled · Operating temperature (°C): 10-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 (single mode fiber output) · M2: <1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-W-473-SM

How is the MLL-W-473-SM output delivered?

Fiber connector: FC/APC · Fiber core diameter: 3.5um,0.10NA. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MLL-W-473-SM require?

Cooled method: Water cooled · Operating temperature (°C): 10-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-W-473-SM deliver?

Transverse mode: TEM00 (single mode fiber output) · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-W-473-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-W-473-SM (current)MSL-S-473-DMSL-U-473
Wavelength473 nm473 nm473 nm
Optical power / pulse energy50~1000 mW1~30 mW1~100 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00 (single mode fiber output)TEM00TEM00