Back to Home

Power stability, linewidth, beam quality

MLL-III-975-SM975 nm near-infrared CW laser

975 nm

MLL-III-975-SM is a 975 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. SM Fiber output laser. Key specifications: output / average power 1~1000 mW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%, fiber type SM fiber, PM fiber optional. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-III-975-SM

21 specification rows

Wavelength975 nm
Output / average power1~1000 mW
Beam / notesSM Fiber output laser
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
Fiber typeSM fiber, PM fiber optional
DIODE LASER AT 975nm Fiber Core diameter4-9μm, 0.12NA
Fiber connectorFC/PC, FC/APC optional
long lifetime, cost-effectiveness and Fiber jacketMetal, PVC optional
Power supply (100-240VAC)PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional
Operating modeCW
Noise of amplitude (rms, 20Hz-20MHz)<1%, <0.5%
Fiber Core diameter4-9μm, 0.12NA
Fiber length1m
Fiber jacketMetal, PVC optional
Transverse modeTEM00
Ellipticity>0.95
M2 after fiber~1.1
Warm-up time (minutes)<5
Cooled methodConduction
Operating temperature (°C)10-35
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MLL-III-975-SM: 975 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MLL-III-975-SM: 975 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MLL-III-975-SM: 975 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MLL-III-975-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: SM fiber, PM fiber optional · DIODE LASER AT 975nm Fiber Core diameter: 4-9μm, 0.12NA
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Conduction · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2 after fiber: ~1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-III-975-SM

How is the MLL-III-975-SM output delivered?

Fiber type: SM fiber, PM fiber optional · DIODE LASER AT 975nm Fiber Core diameter: 4-9μm, 0.12NA. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MLL-III-975-SM require?

Cooled method: Conduction · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-III-975-SM deliver?

Transverse mode: TEM00 · M2 after fiber: ~1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-III-975-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-III-975-SM (current)TEM-LN-975MLL-III-975L
Wavelength975 nm975 nm975 nm
Optical power / pulse energy1~1000 mW1~1000 mW1~200 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00<1.5<1.0