MIL-W-2117 is a 2117 nm CW laser. Used for material processing especially for plastics, ophthalmic surgery, dentistry, suppresses the bleeding during operations. Laser. Key specifications: output / average power 1~2200 mW, operating mode CW, power stability (rms, 4 hours±3℃) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Material processing especially for plastics
MIL-W-2117: Material processing especially for plastics depends on how optical energy is delivered to the target; 2117 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.
Ophthalmic surgery
MIL-W-2117: 2117 nm emission determines compatible optics, coatings and detectors for Ophthalmic surgery. The catalogued beam parameter (<6) helps predict how the source will focus and propagate through the instrument.
Dentistry
MIL-W-2117: 2117 nm emission determines compatible optics, coatings and detectors for Dentistry. The catalogued beam parameter (<6) helps predict how the source will focus and propagate through the instrument.
Suppresses the bleeding during operations
MIL-W-2117: 2117 nm emission determines compatible optics, coatings and detectors for Suppresses the bleeding during operations. The catalogued beam parameter (<6) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect MIL-W-2117 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Air Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <6 · Beam diameter at the aperture (1/e2,mm): <4
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MIL-W-2117
What cooling does the MIL-W-2117 require?+
Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MIL-W-2117 deliver?+
Beam divergence, full angle (mrad): <6 · Beam diameter at the aperture (1/e2,mm): <4. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MIL-W-2117 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.