Back to Home

Power stability, linewidth, beam quality

MIL-W-20962096 nm infrared CW laser

2096 nm

MIL-W-2096 is a 2096 nm CW laser. Used for material processing especially for plastics, ophthalmic surgery, dentistry, suppresses the bleeding during operations. Laser. Key specifications: output / average power 1~2500 mW, operating mode CW, power stability (rms, 4 hours±3℃) <5%, <3%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MIL-W-2096

14 specification rows

Output / average power1~2500 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, 4 hours±3℃)<5%, <3%
Beam divergence, full angle (mrad)<6
Warm-up time (minutes)<10
Cooled methodAir Cooled
Operating temperature (℃)15-35
Power supply (100-240VAC)PSU-W-LED or PUS-W-FDA
Expected lifetime (hours)>10000
Wavelength (nm)2096±6
Output power (mW)1-2500
Beam diameter at the aperture (1/e2,mm)<4
Beam height from base plate (mm)98

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Material processing especially for plastics

MIL-W-2096: Material processing especially for plastics depends on how optical energy is delivered to the target; 2096 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.

Ophthalmic surgery

MIL-W-2096: 2096 nm emission determines compatible optics, coatings and detectors for Ophthalmic surgery. The catalogued beam parameter (<6) helps predict how the source will focus and propagate through the instrument.

Dentistry

MIL-W-2096: 2096 nm emission determines compatible optics, coatings and detectors for Dentistry. The catalogued beam parameter (<6) helps predict how the source will focus and propagate through the instrument.

Suppresses the bleeding during operations

MIL-W-2096: 2096 nm emission determines compatible optics, coatings and detectors for Suppresses the bleeding during operations. The catalogued beam parameter (<6) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MIL-W-2096 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <6 · Beam diameter at the aperture (1/e2,mm): <4
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MIL-W-2096

What cooling does the MIL-W-2096 require?

Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MIL-W-2096 deliver?

Beam divergence, full angle (mrad): <6 · Beam diameter at the aperture (1/e2,mm): <4. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MIL-W-2096 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMIL-W-2096 (current)MIL-W-2117MIL-W-2124
Wavelength2096 nm2117 nm2124 nm
Optical power / pulse energy1~2500 mW1~2200 mW1~2500 mW
Operating mode / pulse widthCWCWCW
Beam quality<6<6<4