Power stability, linewidth, beam quality

MIL-U-1085-SU1085 nm near-infrared CW laser

1085 nm

MIL-U-1085-SU is a 1085 nm CW laser. Used for scientific experiments, optical instrumentation, optical sensing, measurement. Laser. Key specifications: output / average power 1~1000 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MIL-U-1085-SU

15 specification rows

Wavelength1085 nm
Output / average power1~1000 mW
Beam / notesLaser
Operating modeCW
Transverse modeTEM00
M2<1.5
Beam diameter at the aperture (1/e2, mm)~1.0
Warm-up time (minutes)<5
Operating temperature (°C)10-35
Modulation optionalDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Power supply (100-240VAC)PSU-H-FDA/PSU-H-LED/PSU-SR
Expected lifetime (hours)>10000
<1.5
Beam divergence (mrad)<1.5
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Scientific experiments

MIL-U-1085-SU: 1085 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instrumentation

MIL-U-1085-SU: 1085 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical sensing

MIL-U-1085-SU: 1085 nm emission determines compatible optics, coatings and detectors for Optical sensing. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Measurement

MIL-U-1085-SU: Measurement benefits from a stable, focusable source. 1085 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MIL-U-1085-SU to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MIL-U-1085-SU

What cooling does the MIL-U-1085-SU require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MIL-U-1085-SU deliver?

Transverse mode: TEM00 · M2: <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MIL-U-1085-SU with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMIL-U-1085-SU (current)MLL-U-1085-SUMIL-F-1105
Wavelength1085 nm1085 nm1105 nm
Optical power / pulse energy1~1000 mW1~1000 mW1~500 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00