594 nm

MGL-U-594-SF is a 594 nm CW laser. Used for scientific experiments, collimation, laser medical treatment, scientific experiment. Fan cooling and heat sink. Key specifications: output / average power 800~1500 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MGL-U-594-SF

13 specification rows

Wavelength594 nm
Output / average power800~1500 mW
Beam / notesFan cooling and heat sink
Operating modeCW
Transverse modeTEM00
M2~3.0
Cooled methodAir Cooled/ Water Cooled
Warm-up time (minutes)<10
Power supply (100-240VAC)PSU-SF
Expected lifetime (hours)>10000
~3.0
Beam diameter at the aperture (1/e2, mm)~3.0
Beam divergence (mrad)<3.0
Beam height from base plate (mm)108@Air Cooled/ 61.5@Water Cooled

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Scientific experiments

MGL-U-594-SF: 594 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Collimation

MGL-U-594-SF: Collimation benefits from a stable, focusable source. 594 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MGL-U-594-SF: 594 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiment

MGL-U-594-SF: 594 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MGL-U-594-SF to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air Cooled/ Water Cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: ~3.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MGL-U-594-SF

What cooling does the MGL-U-594-SF require?

Cooled method: Air Cooled/ Water Cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MGL-U-594-SF deliver?

Transverse mode: TEM00 · M2: ~3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MGL-U-594-SF with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMGL-U-594-SF (current)MLL-FN-594MGL-FN-594
Wavelength594 nm594 nm594 nm
Optical power / pulse energy800~1500 mW1~50 mW1~100 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00<1.5