Back to Home

Power stability, linewidth, beam quality

MGL-FN-594594 nm orange CW laser

594 nm

MGL-FN-594 is a 594 nm CW laser. Used for collimation, laser medical treatment, scientific experiments, optical instruments. High Stability Orange Laser. Key specifications: output / average power 1~100 mW, operating mode CW, beam divergence (mrad) <1.5. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MGL-FN-594

14 specification rows

Output / average power1~100 mW
Beam / notesHigh Stability Orange Laser
Operating modeCW
Beam divergence (mrad)<1.5
Polarization ratio>100:1, Horizontal (Vertical optional)
Warm-up time (minutes)<5
Pointing stability over temperature (μrad/°C)<8
Operating temperature (°C)10-35
Modulation optionalDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Power supply (100-240VAC)PSU-H-FDA/PSU-H-LED/PSU-SR
Expected lifetime (hours)>10000
Wavelength (nm)594±1
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MGL-FN-594: Collimation benefits from a stable, focusable source. 594 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.5) informs waist size and propagation.

Laser medical treatment

MGL-FN-594: 594 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.

Scientific experiments

MGL-FN-594: 594 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.

Optical instruments

MGL-FN-594: 594 nm emission determines compatible optics, coatings and detectors for Optical instruments. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MGL-FN-594 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence (mrad): <1.5 · Polarization ratio: >100:1, Horizontal (Vertical optional)
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MGL-FN-594

What cooling does the MGL-FN-594 require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MGL-FN-594 deliver?

Beam divergence (mrad): <1.5 · Polarization ratio: >100:1, Horizontal (Vertical optional). Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MGL-FN-594 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMGL-FN-594 (current)MLL-FN-594MGL-W-594A
Wavelength594 nm594 nm594 nm
Optical power / pulse energy1~100 mW1~50 mW100~800 mW
Operating mode / pulse widthCWCWCW
Beam quality<1.5TEM00Near TEM00