MDL-III-1580-SLD-SM is a 1580 nm Fiber laser. Used for medical imaging, flow cytometry, dna sequencing, measurement. Fiber output High Stability Infrared Laser. Key specifications: output / average power 1~17 mW. View specifications, datasheet and enquiry options from Precisometer.
Engineering context for a thin Fiber Lasers record
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 5 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Typical operating fields in the series
• Output / average power: 1~20 mW
• Output / average power: 1~15 mW
• Output / average power: 1~17 mW
Beam-quality tolerance context
M², full-angle divergence and pointing stability are not present in this thin record. Treat all three as required order-confirmation fields because they determine focusability, propagation and alignment drift.
Optical integration schematic
Step 1Laser source and internal thermal control
Step 2Configured fiber launch or integrated pigtail
Step 3Mode- and connector-matched patch lead
Step 4Collimator, isolator or experiment input
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Medical imaging
MDL-III-1580-SLD-SM: 1580 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Flow cytometry
MDL-III-1580-SLD-SM: 1580 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
DNA sequencing
MDL-III-1580-SLD-SM: 1580 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Measurement
MDL-III-1580-SLD-SM: Measurement benefits from a stable, focusable source. 1580 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MDL-III-1580-SLD-SM with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.