Specifications

MDL-C-705

2 specification rows

Wavelength705 nm
Output / average power1~10 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 2 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~500 mW
  • Output / average power: 1~20 mW

Beam-quality tolerance context

M², full-angle divergence and pointing stability are not present in this thin record. Treat all three as required order-confirmation fields because they determine focusability, propagation and alignment drift.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.

Flow cytometry

MDL-C-705: 705 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

MDL-C-705: 705 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

MDL-C-705: 705 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Holography

MDL-C-705: 705 nm emission determines compatible optics, coatings and detectors for Holography. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-C-705 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-C-705 (current)FC-705FC-OEM-705
Wavelength705 nm705 nm705 nm
Optical power / pulse energy1~10 mW1~500 mW15 mW
Operating mode / pulse widthConfirm for this modelConfirm for this modelCW
Beam qualityConfirm for this modelConfirm for this model1.1