Back to Home

Fiber output, PM options, seed formats

MBL-W-473-SM473 nm blue fiber laser

473 nm

MBL-W-473-SM is a 473 nm Fiber laser. Used for medical imaging, flow cytometry, dna sequencing, measurement. Features: SM Fiber. Key specifications: output / average power 50~1000 mW, spectral linewidth < 0.1 nm, power stability <2%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MBL-W-473-SM

23 specification rows

Output / average power50~1000 mW
Spectral linewidth< 0.1 nm
Power stability<2%
Beam / notesFeatures: SM Fiber
Operating modeCW
Transverse modeTEM00 (single mode fiber output)
M2<1.1
Polarization (optional)>50:1 after PM fiber
Fiber typeSM fiber (PM fiber optional)
Fiber connectorFC/APC
Fiber length1m
Fiber JacketPVC, Metal optional
Warm-up time (minutes)<10
Cooled methodAir cooled / Water cooled
Operating temperature (°C)10-30
Power supply (100-240VAC)PSU-W-LED
Expected lifetime (hours)>10000
FeaturesSM Fiber
Wavelength (nm)473±1
Output power (mW)50-1000
<1.1
Fiber core diameter3.5um,0.10NA
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Medical imaging

MBL-W-473-SM: 473 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MBL-W-473-SM: 473 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MBL-W-473-SM: 473 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%) helps keep measured intensity changes attributable to the sample rather than source drift.

Measurement

MBL-W-473-SM: Measurement benefits from a stable, focusable source. 473 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00 (single mode fiber output)) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MBL-W-473-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air cooled / Water cooled · Operating temperature (°C): 10-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 (single mode fiber output) · M2: <1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MBL-W-473-SM

How is the MBL-W-473-SM output delivered?

Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MBL-W-473-SM require?

Cooled method: Air cooled / Water cooled · Operating temperature (°C): 10-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MBL-W-473-SM deliver?

Transverse mode: TEM00 (single mode fiber output) · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MBL-W-473-SM with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMBL-W-473-SM (current)MBL-S-473-SMFC-W-462C
Wavelength473 nm473 nm462 nm
Optical power / pulse energy50~1000 mW1~50 mW30~40 W
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityTEM00 (single mode fiber output)TEM00 (single mode fiber output)Confirm for this model