Back to Home

Power stability, linewidth, beam quality

MBL-III-473-AOM473 nm blue CW laser

473 nm

MBL-III-473-AOM is a 473 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Features: Air Cooled. Key specifications: output / average power 1~50 mW, spectral linewidth < 0.2 nm, power stability <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MBL-III-473-AOM

21 specification rows

Output / average power1~50 mW
Spectral linewidth< 0.2 nm
Power stability<1%
Beam / notesFeatures: Air Cooled
Operating modeCW
Transverse modeTEM00
M2<1.5
Polarization ratio>100:1, Vertical (Horizontal optional)
Warm-up time (minutes)<10
Operating temperature (°C)10-35
Modulation optionalDC-1MHz; TTL or Analog optional
Power supply (100-240VAC)PSU-III-FDA-AOM
Expected lifetime (hours)>10000
CoolingAir Cooled
Wavelength (nm)473±1
Output power (mW)1-50
<1.5
Beam diameter at the aperture (1/e2, mm)<1.0
Beam divergence (mrad)<1.5
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)24.8

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MBL-III-473-AOM: 473 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MBL-III-473-AOM: 473 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MBL-III-473-AOM: 473 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

MBL-III-473-AOM: 473 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect MBL-III-473-AOM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35 · Cooling: Air Cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MBL-III-473-AOM

What cooling does the MBL-III-473-AOM require?

Operating temperature (°C): 10-35 · Cooling: Air Cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MBL-III-473-AOM deliver?

Transverse mode: TEM00 · M2: <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MBL-III-473-AOM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMBL-III-473-AOM (current)MSL-S-473-DMSL-U-473
Wavelength473 nm473 nm473 nm
Optical power / pulse energy1~50 mW1~30 mW1~100 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00