FC-W-447H-II is a 447 nm Fiber laser. Used for medical imaging, flow cytometry, dna sequencing, measurement. 447nm Violet Blue Laser. Key specifications: output / average power 50~200 W, operating mode CW, cooled method Water cooled. View specifications, datasheet and enquiry options from Precisometer.
DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Medical imaging
FC-W-447H-II: 447 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
FC-W-447H-II: 447 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
FC-W-447H-II: 447 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Measurement
FC-W-447H-II: Measurement benefits from a stable, focusable source. 447 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
System integration
Integration and compatibility
Use these checks to connect FC-W-447H-II to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Water cooled · Operating temperature (℃): 0-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Technical FAQ
Integration questions for FC-W-447H-II
How is the FC-W-447H-II output delivered?+
Fiber Core Diameter (um): 200, 400, 600, 0.22NA · Fiber Connector: SMA905, FC, QBH optional. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
What cooling does the FC-W-447H-II require?+
Cooled method: Water cooled · Operating temperature (℃): 0-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.