Back to Home

Power stability, linewidth, beam quality

FC-EW-532532 nm green CW laser

532 nm

FC-EW-532 is a 532 nm CW laser. Beam distribution: uniform speckle-free illumination; Dimension (mm): 408 x 290 x 133; Standard Fiber: Armoured 1.5m (other length available); Beam diameter at aperture (mm): ¢ 3, ¢ 5, ¢ 8, ¢ 10; Beam size with collimator: 20cm beam diameter at 50cm location; LED Display: Diode current. Key specifications: operating mode CW, TTL or Analog on request, output / average power 5-10 W, expected lifetime 10000 hours. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-EW-532

4 specification rows

Wavelength532 nm
Operating modeCW, TTL or Analog on request
Output / average power5-10 W
Beam / notesBeam distribution: uniform speckle-free illumination; Dimension (mm): 408 x 290 x 133; Standard Fiber: Armoured 1.5m (other length available); Beam diameter at aperture (mm): ¢ 3, ¢ 5, ¢ 8, ¢ 10; Beam size with collimator: 20cm beam diameter at 50cm location; LED Display: Diode current
Expected lifetime10000 hours

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 20~35 W
  • Output / average power: 45~75 W
  • Output / average power: 1.5~2.5 W
  • Operating mode: CW
  • Operating mode: High modulation up to 1 MHz

Beam-quality tolerance context

Nearby series records state M²: 10, M²: <1.2, M²: <1, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for FC-EW-532; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser source and internal thermal control
  2. Step 2Configured fiber launch or integrated pigtail
  3. Step 3Mode- and connector-matched patch lead
  4. Step 4Collimator, isolator or experiment input

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

FC-EW-532: 532 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

FC-EW-532: Laboratory measurement benefits from a stable, focusable source. 532 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-EW-532 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-EW-532 (current)HPL-532-PAHPL-532-PB
Wavelength532 nm532 nm532 nm
Optical power / pulse energy5-10 W1~10 W1~25 W
Operating mode / pulse widthCW, TTL or Analog on requestQ-switchedQ-switched
Beam qualityConfirm for this model<1<1