Back to Home

Power stability, linewidth, beam quality

FC-D-690690 nm red CW laser

690 nm

FC-D-690 is a 690 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Laser. Key specifications: output / average power 1~450 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-D-690

2 specification rows

Wavelength690 nm
Output / average power1~450 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 8 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~250 mW
  • Output / average power: 1~1300 mW
  • Output / average power: 1~200 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state Beam divergence, full angle (mrad): <1.0, Beam divergence, full angle (mrad): <3.0, and Beam divergence, full angle (mrad): ~10 / ~20. These are series context, not guaranteed values for FC-D-690; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

FC-D-690: 690 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

FC-D-690: 690 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

FC-D-690: 690 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Collimation

FC-D-690: Collimation benefits from a stable, focusable source. 690 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-D-690 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-D-690 (current)MLL-III-690LMLL-III-690
Wavelength690 nm690 nm690 nm
Optical power / pulse energy1~450 mW1~250 mW1~1300 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelNear TEM00<3.0