Back to Home

Power stability, linewidth, beam quality

FC-D-660660 nm red CW laser

660 nm

FC-D-660 is a 660 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Frequency shift (pm) (over ±2°C and 2hrs): <20. Key specifications: output / average power 1~200 mW, spectral linewidth 0.1 nm, (0.06 optional), power stability <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-D-660

19 specification rows

Output / average power1~200 mW
Spectral linewidth0.1 nm, (0.06 optional)
Power stability<3%, <2%, <1%
Optical noise<1%
Beam / notesFrequency shift (pm) (over ±2°C and 2hrs): <20
Operating modeCW
Fiber core diameter100µm, 0.22 NA
Fiber connectorSMA905, FC/PC optional
Fiber jacketMetal, PVC optional
Warm-up time (minutes)<5
Cooled methodAir cooled
Operating temperature (℃)20-30
Operating voltage (VDC)5V/6A
Expected lifetime (hours)>10000
Central wavelength (nm)660±2
Fiber length1m
Output power after fiber (mW)1-200
Frequency shift (pm) (over ±2°C and 2hrs)<20
Noise of amplitude (rms, 20Hz-20MHz)<1%

Applications

Typical uses for lasers of this wavelength and type in this catalogue.

  • Flow cytometry
  • DNA sequencing
  • Medical imaging
  • Collimation
  • Laser medical treatment

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.