Back to Home

Power stability, linewidth, beam quality

FC-405405 nm violet high-power CW laser

405 nm

FC-405 is a 405 nm CW laser. 2-in-1 laser and fiber combiner. Key specifications: output / average power 1~30 W, operating mode CW, fiber connector SMA905, FC/PC optional. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-405

16 specification rows

Output / average power1~30 W
Beam / notes2-in-1 laser and fiber combiner
Operating modeCW
Fiber connectorSMA905, FC/PC optional
Cooled methodAir cooled
Operating temperature (℃)10-35
Operating voltage (VAC)100-240
Expected lifetime (hours)>10000
Central wavelength (nm)405±5
Output power after fiber (W)1-30
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
Fiber core diameter400µm, 0.22 NA
Fiber length1m
Fiber jacketMetal, PVC optional
Warm-up time (minutes)<5
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

FC-405: 405 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

FC-405: Laboratory measurement benefits from a stable, focusable source. 405 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

System integration

Integration and compatibility

Use these checks to connect FC-405 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber connector: SMA905, FC/PC optional · Fiber core diameter: 400µm, 0.22 NA
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for FC-405

How is the FC-405 output delivered?

Fiber connector: SMA905, FC/PC optional · Fiber core diameter: 400µm, 0.22 NA. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the FC-405 require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-405 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-405 (current)MSL-T-405MDL-C-405
Wavelength405 nm405 nm405 nm
Optical power / pulse energy1~30 W1~80 mW1~50 mW
Operating mode / pulse widthCWCWCW
Beam qualityConfirm for this model<1Multimode