CW-760~840 is a 793 nm CW laser. Used for optical microscope, photon imaging, physics experiment. Tunable Wavelength Infrared Laser. Key specifications: output / average power 1~2000 mW, operating mode Pulsed, single pulse energy (nj) 0.1-0.6. View specifications, datasheet and enquiry options from Precisometer.
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Optical microscope
CW-760~840: 793 nm emission can be matched to the absorption or excitation band used in Optical microscope. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Photon imaging
CW-760~840: 793 nm emission can be matched to the absorption or excitation band used in Photon imaging. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Physics experiment
CW-760~840: Physics experiment benefits from a stable, focusable source. 793 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
System integration
Integration and compatibility
Use these checks to connect CW-760~840 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2 factor: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for CW-760~840
What cooling does the CW-760~840 require?+
Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the CW-760~840 deliver?+
Transverse mode: TEM00 · M2 factor: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare CW-760~840 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.