Back to Home
Precisometer · Official representative

Photovoltaic inspection

LumiSolar Professional

Module inspection in the laboratory, with an enclosed electroluminescence measurement setup.

LumiSolar Professional

Representative manufacturer photograph; housing and connectors depend on the selected configuration. Select the photograph to enlarge.

Measurement
Electroluminescence
Configuration
Application-specific system; discuss sample size and measurement workflow

From photon to signal

Response for your configuration.

Full specifications

A single QE curve is not specified for this complete PV-inspection system. Camera response depends on the installed detector and the emission spectrum of the cell or module. EL/PL detector QE must also be distinguished from an EQE measurement of the photovoltaic device itself.

The details behind the selection

Full technical specifications.

Compare sensor configurations, coating options, operating limits and integration details directly below. Check the operating mode and temperature alongside each performance value.

01

8Mpx — dimensions & configuration

6 parameters
8Mpx — dimensions & configuration
ParameterPublished specification
Dimensions (W:D:H)2460 x 1400 x 2000 mm
Weight250 kg
Scanning Directions1 axis
Imaging Unit1 or 2 scientific CCD cameras
Size of Module or Stringmax. 1.1 x 2.0 m
Image Resolutionup to 8 Mpx
02

32Mpx — dimensions & configuration

6 parameters
32Mpx — dimensions & configuration
ParameterPublished specification
Dimensions (W:D:H)2460 x 1400 x 2000 mm
Weight250 kg
Scanning Directions1 axis
Imaging Unit2 scientific CCD cameras
Size of Module or Stringmax. 1.0 x 2.0 m
Image Resolutionup to 34 Mpx
03

75Mpx — dimensions & configuration

6 parameters
75Mpx — dimensions & configuration
ParameterPublished specification
Dimensions (W:D:H)customer specific
Weightcustomer specific
Scanning Directions1 axis
Imaging Unit1 scientific CCD camera
Size of Module or Stringmedium to large formats
Image Resolutionup to 240 Mpx
04

System common specifications

5 parameters
System common specifications
ParameterPublished specification
Power supplyStandard ~230V, 50/60 Hz
PC interfaceUSB
SystemPC, industrial PC
Automatic EL image analysisfor c-Si solar modules
Typical exposure times0.3 sec - 60 sec (depending on size and type of cell, string or module)
05

Published configuration scope

2 parameters
Published configuration scope
ParameterPublished specification
MeasurementElectroluminescence
ConfigurationApplication-specific system; discuss sample size and measurement workflow

Successfully tested on various Solar Module types

  • Monocrystalline Silicon (mono-Si)
  • Amorphous Silicon (a-Si)
  • Copper Indium Gallium Selenide (CIGS)
  • Heterojunction with Intrinsic Thin Layer (HIT)
  • Polycrystalline Silicon (poly-Si)
  • Copper Indium Sulfide (CIS)
  • Cadmium Telluride (CdTe)

Inspection capabilities:

  • Shunt detection
  • Dead cells
  • Broken cells
  • Inhomogeneities and impurities
  • Micro-crack identification
  • Finger defects
  • Hotspots

Features & Benefits

  • Professional Electroluminescence imaging Turnkey system delivering quick measurements
  • Scientific camera systems Excellent sensitivity, image quality and contrast
  • Suitable for different module sizes Supports different types and sizes
  • Easy Operation With simple slot-in mechanism
  • Flexible design and configuration

Software Features

  • Remote control of module power supply
  • Automated EL image analysis for c-Si
  • Dimension measurements of defects
  • Automatic background subtraction
  • Single shot, videomode, scanmode
  • Positioning functions
  • Load and save images, Quicksave
  • BMP, JPEG, TXT, and raw data
  • False-colour represenation of images
  • Intensity profiles in x-, y-direction
  • Different scaling and zooming functions
  • Windows XP / Vista / 7 / 10
  • USB 2.0 Interfaces

Build your enquiry

Start with your application.

Capture the system requirements and integration details you want to discuss with Precisometer.

LumiSolar Professional configuration and enquiry

Tell us about your experiment so we can specify the system with you.

Your starting configuration

LumiSolar Professional

Measurement
Electroluminescence
Configuration
Application-specific system; discuss sample size and measurement workflow

Selected options are requirements for discussion. Compatibility and final performance are confirmed for your configuration.

Review enquiry

Discuss selection, integration and a quotation with Precisometer.

Technical overview

Designed around the measurement.

Module inspection in the laboratory, with an enclosed electroluminescence measurement setup.

Laboratory module inspectionFailure analysis
LumiSolar Professional technical overview
MeasurementElectroluminescence
ConfigurationApplication-specific system; discuss sample size and measurement workflow

Explore the wider range

Other routes to your measurement.

All Greateyes products
Product selection

What do you need to measure?

Start with your signal, or search directly for a camera, sensor option or application.

6 product ranges · 0 camera configurations

LumiSolar Professional Inline

Representative equipment; the complete configuration depends on your application.

Greateyes / Photovoltaic inspection

LumiSolar Professional Inline

Electroluminescence module inspection integrated into photovoltaic production workflows.

Measurement
Electroluminescence
Configuration
Application-specific system; discuss sample size and measurement workflow
Explore the solution
LumiSolar Mobile

Representative equipment; the complete configuration depends on your application.

Greateyes / Photovoltaic inspection

LumiSolar Mobile

A portable electroluminescence camera system for flexible solar-cell and module inspection.

Measurement
Electroluminescence
Configuration
Application-specific system; discuss sample size and measurement workflow
Explore the solution
LumiSolar Outdoor

Representative equipment; the complete configuration depends on your application.

Greateyes / Photovoltaic inspection

LumiSolar Outdoor

Battery-powered electroluminescence inspection of installed solar modules after twilight or at night.

Measurement
Electroluminescence
Configuration
Application-specific system; discuss sample size and measurement workflow
Explore the solution
LumiSolarCell EL

Representative equipment; the complete configuration depends on your application.

Greateyes / Photovoltaic inspection

LumiSolarCell EL

Electroluminescence characterisation of photovoltaic cells, including reverse-biased EL.

Measurement
EL
Configuration
Application-specific system; discuss sample size and measurement workflow
Explore the solution
LumiSolarCell PL

Representative equipment; the complete configuration depends on your application.

Greateyes / Photovoltaic inspection

LumiSolarCell PL

Contactless photoluminescence characterisation of solar cells and wafers using LED excitation.

Measurement
PL
Configuration
Application-specific system; discuss sample size and measurement workflow
Explore the solution
LumiSolarCell EL PL

Representative equipment; the complete configuration depends on your application.

Greateyes / Photovoltaic inspection

LumiSolarCell EL PL

Combined electroluminescence and photoluminescence in a compact photovoltaic characterisation system.

Measurement
EL PL
Configuration
Application-specific system; discuss sample size and measurement workflow
Explore the solution