Back to Home

Low Light Imaging/Semiconductor Cooled Camera

MTR3CMOS02300KMA

MTR3CMOS02300KMA Low Light Imaging/Semiconductor Cooled Camera with SC2110 (M, RS) sensor, 2.3MP (1920×1200) for professional imaging.

Sensor
SC2110 (M, RS)
Resolution
2.3MP (1920×1200)
Pixel Size
12 µm × 12 µm
Frame Rate
120 fps @ 1920×1200
Interface
USB3.0
MTR3CMOS02300KMA

Application context

Why this design is used

Scientific imaging

MTR3CMOS02300KMA: The SC2110 (M, RS) sensor, 2.3MP (1920×1200) resolution, and 12 µm × 12 µm pixels defines the sensitivity, sampling and field coverage available for Scientific imaging. The 120 fps @ 1920×1200 frame-rate listing also sets the fastest full-frame acquisition regime.

Instrument integration

MTR3CMOS02300KMA: The SC2110 (M, RS) sensor, 2.3MP (1920×1200) resolution, and 12 µm × 12 µm pixels defines the sensitivity, sampling and field coverage available for Instrument integration. The 120 fps @ 1920×1200 frame-rate listing also sets the fastest full-frame acquisition regime.

Specifications

MTR3CMOS02300KMA

23 specification rows

The MTR3CMOS02300KMA is a low-light & cooled camera in the MTR3CMOS series, built around a SC2110 (M, RS) sensor, 2.3MP (1920×1200) resolution, 12 µm × 12 µm pixels, frame rates up to 120 fps @ 1920×1200, a USB3.0 interface. It suits low light imaging/semiconductor cooled camera where reliable imaging performance and interface compatibility matter.

Key Parameters

ModelMTR3CMOS02300KMA
SensorSC2110 (M, RS)
Effective Pixels / Resolution2.3MP (1920×1200)
Frame Rate (Full Resolution and Key Resolution Modes)120 fps @ 1920×1200
Exposure Time0.1 ms ~ 1 h
Shutter TypeRolling Shutter
Color TypeMonochrome

Imaging Performance

Pixel Size12 µm × 12 µm
Sensor Size23.0 mm × 14.4 mm
Diagonal1.8" (27.14 mm)
Dynamic RangeAvailable on request
Bit Depth8/12-bit
Sensitivity120000 mV/lux·s @HCG

Interface & Mechanical

Data InterfaceUSB3.0
GPIOAvailable on request
Lens MountC-mount
DimensionsCircular or square housing optional
WeightAvailable on request
Power SupplyUSB3.0 interface power + external DC 12 V 3 A cooling power supply

Environment & Certification

Operating Temperature / Humidity10 °C ~ +50 °C / 30%~80%RH
Storage Temperature / Humidity20 °C ~ +60 °C / 10%~60%RH
OS SupportWindows/Linux/macOS/Android multi-platform SDK (native C/C++, C#/VB.NET, Python, Java, DirectShow, TWAIN, etc.)
CertificationCE, FCC

System integration

Integration and compatibility

Use these checks to connect MTR3CMOS02300KMA to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Lens and microscope interface
Lens Mount: C-mount
Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.
Sensor and sampling
Sensor: SC2110 (M, RS) · Resolution: 2.3MP (1920×1200)
Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.
Interface and data rate
Frame Rate: 120 fps @ 1920×1200 · Interface: USB3.0
Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.
Hardware synchronization
GPIO: Available on request
Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.
Cooling and noise floor
Dynamic Range: Available on request
Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Technical FAQ

Integration questions for MTR3CMOS02300KMA

What lens mount is required for the MTR3CMOS02300KMA?

Lens Mount: C-mount. Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.

What sensor and pixel pitch does the MTR3CMOS02300KMA use?

Sensor: SC2110 (M, RS) · Resolution: 2.3MP (1920×1200). Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.

How does the MTR3CMOS02300KMA connect to the acquisition computer?

Frame Rate: 120 fps @ 1920×1200 · Interface: USB3.0. Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.

Does the MTR3CMOS02300KMA support hardware triggering?

GPIO: Available on request. Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.

What is the noise performance of the MTR3CMOS02300KMA?

Dynamic Range: Available on request. Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Need help choosing?

Tell us your sensor, resolution, spectral range, frame-rate, interface, and software requirements and we will confirm the matching configuration and lead time.

Open camera finder

Model selection

Nearby series comparison

Compare MTR3CMOS02300KMA with the closest available models in the MTR3CMOS family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMTR3CMOS02300KMA (current)MTR3CMOS01700KPAMTR3CMOS02300KPA
SensorSC2110 (M, RS)IMX432 (C, GS)SC2110 (C, RS)
Resolution2.3MP (1920×1200)1.7MP (1600×1100)2.3MP (1920×1200)
Sensor size23.0 mm × 14.4 mm14.4 mm × 9.9 mm23.0 mm × 14.4 mm
Pixel size / frame rate12 µm × 12 µm9.0 µm × 9.0 µm12 µm × 12 µm

Other cameras on the SC2110 sensor

The SC2110 appears in 4 models across the catalogue, differing in cooling, shutter, interface and colour filter. Compare them side by side before settling on a variant.