PA300-Z-P4 Motorized Vertical Stage
Motorized vertical stage with 300 mm travel and a 150×150 mm table. Transmission: precision ball screw φ16×5; guide: linear-slider guides. Repositioning accuracy ≤±3 µm. Vertical load capacity 15 kg (centred).
- Travel range
- 300 mm
- Repositioning accuracy
- ≤±3 µm
- Table size
- 150×150 mm
- Transmission mechanism
- Precision ball screw φ16×5
Specifications
Mechanical
| Travel range (mm) | 300 |
|---|---|
| Table size (mm) | 150×150 |
| Transmission mechanism | Precision ball screw φ16×5 |
| Guide mechanism | Linear-slider guides |
| Body material and finish | Black anodized aluminum alloy |
Accuracy
| Single-direction positioning accuracy (µm) | ≤30 |
|---|---|
| Repositioning accuracy (µm) | ≤±3 |
| Static clearance (µm) | ≤3 |
| Backlash (µm) | ≤5 |
| Static parallelism (mm) | ≤0.1 |
| Dynamic straightness (µm) | ≤25 |
| Dynamic parallelism (µm) | ≤30 |
| Yaw (arcsec) | ≤50 |
| Pitch (arcsec) | ≤60 |
Sensors & connection
| Limit sensors (built-in) | 2×PM-L25 (SUNX, Japan) |
|---|---|
| Origin sensor (built-in) | 1×PM-L25 (SUNX, Japan) |
| Sensor supply voltage | DC5~24V±10% |
| Sensor output | NPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA) |
| Sensor output logic | Position limit sensor: output ON when sensor is blocked; Origin-point sensor: output OFF when sensor is blocked; |
Load capacity
| Vertical load capacity, centred (kg) | 15 |
|---|