Zolix · Motorized Stages
GON140-80-ST528 Motorized Goniometer
Motorized goniometer with ±3° tilt range, an 80×80 mm table and a 140 mm rotation-centre height. Transmission: ball screws φ6×1; guide: arc crossed-roller guide+linear-slider guides. Repositioning accuracy ≤±0.001°. Horizontal load capacity 5 kg. With -ST528 (five-phase 28 stepping motor).
- Repositioning accuracy
- ≤±0.001°
- Horizontal load capacity
- 5 kg
- Table size
- 80×80 mm
- Rotation centre height
- 140 mm
Specifications
Mechanical
| Rotation centre height (mm) | 140 |
|---|---|
| Table size (mm) | 80×80 |
| Angle range (°) | ±3 |
| Transmission mechanism | Ball screws φ6×1 |
| Guide mechanism | Arc crossed-roller guide+linear-slider guides |
| Body material and finish | Black anodized aluminum alloy |
Accuracy
| Repositioning accuracy (°) | ≤±0.001 |
|---|---|
| Static clearance (°) | ≤0.003 |
| Backlash (°) | ≤0.003 |
| Swing accuracy at rotation centre (mm) | ≤0.01 |
Sensors & connection
| Limit sensors (built-in) | 2×GP1S09xHCPI (SHARP, Japan) |
|---|---|
| Origin sensor (built-in) | 1×GP1S09xHCPI (SHARP, Japan) |
| Sensor supply voltage | DC5~24V±10% |
| Sensor output | NPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA) |
| Sensor output logic | Output ON when sensor is blocked |
Load capacity
| Horizontal load capacity (kg) | 5 |
|---|---|
| Inverted load capacity (kg) | 1.5 |
| Vertical load capacity (kg) | 2 |
Compatible controllers
For the five-phase 28 stepping motor this stage uses.