Back to Home

Raman, spectrometer, spectral diagnostics

Micro Raman Spectrum Measurement System

It combines micro system and Raman system which facilitates the Raman micro area detection.

Micro Raman Spectrum Measurement System

Product Specifications

Micro Raman Spectrum Measurement System

49 specification rows

Specifications

ParameterValue
Microscope modelGMM-580
Z-axis focusing systemCoarse and fine Coaxial focus Minimum graduation: 2μm, Limit stopper device
X / Y Mobile stages size210mm*140mm
Stage moving range75mm*50mm
Camera5 Megapixel Imaging System GMW500
Microscope objective5X-100X (Optional)

Specifications

ParameterValue
ChipCMOS, colorized, progressive scanning
Chip size1 / 2.5 inch
Effective pixels5 million
Pixels size2.2μm*2.2μm
Max Resolution (H×V)2592*1944
Frame rate5fps@2592 ×1944 18fps@1280×960 60fps@ 640 ×480
Exposure time0.21~2000ms
Noise of amplitude40.5dB
Operating temperature(°C)10 ~ 50
Data interfaceHigh speed USB2.0
Lens mountStandard C-mount

Specifications

Field 1Field 2Field 3Field 4Field 5Field 6Field 7
Wavelength (nm)405 ±0.5488±0.5532±0.5633±0.5785±0.3830 ±5
ModeSingleSingleSingleSingleSingleMulti
Spectral line width (cm-1)1.83.5 / 1.23.5 / 0.1<0.7<3.2<28
Output power (mW)1-5001-1501-10001-801-5001-900
Power stability (pk-pk, 4 hours)<1%, <3%, <5%<1%, <3%, <5%<1%, <3%, <5%<1%, <3%, <5%<1%, <3%, <5%<1%, <3%, <5%
Parameter of fiber100um@0.22NA100um@0.22NA100um@0.22NA100um@0.22NA100um@0.22NA100um@0.22NA
Noise of amplitude(rms)-<1%<0.5%<1%<0.5%, <1%<1%
Operating modeCWCWCWCWCWCW
Warm-up time(minutes)<5<5<10<5<5<5
Operating temperature (℃)10-3510-3515-3510-3510-4010-35
Expected lifetime (hours)100001000010000100001000010000
Warranty1 year1 year1 year1 year1 year1 year
Data Sheet------

Specifications

Field 1Field 2Field 3Field 4Field 5Field 6Field 7
Wavelength range405-461nm (405nm excitation)488-572nm (488nm excitation)532-700nm (532nm excitation)633-781nm (633nm excitation)785-1100nm (785nm excitation)830- 1000nm (830nm excitation)
Optical resolution8-12cm -1 (405nm excitation)8-12cm -1 (488nm excitation)8-12cm -1 (532nm excitation)8-12cm -1 (633nm excitation)5-8cm -1 (785nm excitation)5-7cm -1 (830nm excitation)
Pixels2048 pixels-----
Pixels size14um*14um-----
Dimensions (mm)149*109*50-----
Weight (g)1000-----
Signal-to-noise ratio1000: 1-----
Integration time17ms-10s-----
Power consumption450mA@5VDC-----
Data transfer speedFull scans into memory every 4 milliseconds with USB 2.0 Full scans into memory every 18 milliseconds with USB 1.1-----
Connector30pin connector-----

Specifications

Field 1Field 2Field 3Field 4Field 5Field 6Field 7
Excitation wavelength (nm)405488532633785±830
Probe focus length (mm)7.5-----
Probe main materialProbe material is 2A12 after Blackening; Stainless steel detector tip-----
Fiber configurationTwo single fiber (100um excitation fiber, 200um optical fiber for collecting light); N.A.=0.22, PVC / metal sheath; 1m Length-----

Specifications

ParameterValue
Optical spectrum analysisSpectral Analysis / Raman Analysis 2.0
Operating systemWindows XP / Win7 / Win10 (32bits or 64 bits)

Product variants

  • Features Adjustable laser with stable frequency, avoiding wavelength drift and damage of samples. Optimization of the confocal module, ensuring that focal plane of the laser and view focal plane of the objective confocal. Detector with high stability, improving the spectral acquisition efficiency and accuracy. Modular design, self-assembly, simple operation and easy to carry. Wavelength range and resolution can be customized.
  • Application Identify microns impurities of the pills and describe the distribution. Distinguish the effective active ingredient and accessories in pills. Describing the distribution and density of occurrence. Positioning precisely the boundary of different particles in ore or arts. Describing and locating material contained within mineral or rock. The identification of trace material evidence, such as the drug, medicine, explosives, textile and so on.

Need this configured?

Share wavelength range, measurement target, detector needs, sample geometry, software and interface requirements, and we will qualify the matching configuration.

View enquiry list