Power stability, linewidth, beam quality
MDL-XS-976976 nm near-infrared CW laser
976 nmMDL-XS-976 is a 976 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Low Noise Infrared Laser. Key specifications: output / average power 1~50 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
MDL-XS-976
20 specification rows
| Output / average power | 1~50 mW |
|---|---|
| Beam / notes | Low Noise Infrared Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1%, <0.5% |
| Transverse mode | Near TEM00 |
| Noise of amplitude (rms, 20Hz-20MHz) | <1%, <0.5% |
| M2 | ~1.5 |
| Beam divergence, full angle (mrad) | <1.0 |
| Warm-up time (minutes) | <5 |
| monitoring, | inspection |
| Operating temperature (℃) | 10-35 |
| Operating voltage (VDC) | 12V/4A |
| Modulation option | AMOD (Analog) DC-100kHz |
| Expected lifetime (hours) | >10000 |
| Central wavelength (nm) | 976±10 |
| Output power (mW) | 1-50 |
| M² | ~1.5 |
| Beam diameter at the aperture (1/e2,mm) | ~1.2 |
| Polarization ratio | >10:1, (>50:1 optional) Horizontal±5 degree (Vertical optional) |
| Beam height from base plate (mm) | 19 |
Applications
Uses named on the datasheet for this product line.
- Medical imaging
- Flow cytometry
- DNA sequencing
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related cw lasers
Compare the MDL-XS-976 with nearby cw lasers across the wavelength range.