Power stability, linewidth, beam quality
MDL-III-642642 nm red CW laser
642 nmMDL-III-642 is a 642 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. High Stability Red Laser. Key specifications: output / average power 1~200 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
MDL-III-642
17 specification rows
| Output / average power | 1~200 mW |
|---|---|
| Beam / notes | High Stability Red Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1%, <0.5% |
| M2 | <1.5 / <1.2 |
| Beam divergence, full angle (mrad) | <1.0 |
| Warm-up time (minutes) | <5 |
| Cooled method | Conduction |
| Operating temperature (°C) | 10-35 |
| Power supply (100-240VAC) | PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM |
| Expected lifetime (hours) | >10000 |
| Central wavelength (nm) | 642±5 |
| Output power (mW) | 1-200 |
| Transverse mode | Near TEM00 |
| Polarization ratio | >50:1, (>100:1 optional) Horizontal±5 degree (Vertical optional) |
| Beam height from base plate (mm) | 24.8 |
| Modulation option | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional |
Applications
Uses named on this model’s datasheet.
- Medical imaging
- Flow cytometry
- DNA sequencing
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related cw lasers
Compare the MDL-III-642 with nearby cw lasers across the wavelength range.