MDL-III-1060L1060 nm near-infrared CW laser
1060 nmMDL-III-1060L is a 1060 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Near TEM 00. Key specifications: output / average power 1~200 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
MDL-III-1060L
16 specification rows
| Output / average power | 1~200 mW |
|---|---|
| Beam / notes | Near TEM 00 |
| Operating mode | CW |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1%, <0.5% |
| Beam divergence, full angle (mrad) | <1.0 |
| Warm-up time (minutes) | <5 |
| Cooled method | Conduction |
| Operating temperature (°C) | 10-35 |
| Power supply (100-240VAC) | PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM |
| Expected lifetime (hours) | >10000 |
| Central wavelength (nm) | 1060±5 |
| Output power (mW) | 1-200 |
| Transverse mode | Near TEM00 |
| Beam diameter at the aperture (1/e2, mm) | ~3.5 |
| Beam height from base plate (mm) | 24.8 |
| Modulation option | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional |
Applications
Uses named on this model’s datasheet.
- Medical imaging
- Flow cytometry
- DNA sequencing
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related cw lasers
Compare the MDL-III-1060L with nearby cw lasers across the wavelength range.