Back to Home

Power stability, linewidth, beam quality

UN-Ti-740-840740 nm red CW laser

740 nm

UN-Ti-740-840 is a 740 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Water cooled. Key specifications: output / average power 1~7000 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

UN-Ti-740-840

2 specification rows

Wavelength740 nm
Output / average power1~7000 mW
Beam / notesWater cooled

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 16 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~2000 mW
  • Output / average power: 1~3 W
  • Output / average power: 1~50 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state M²: <1.1, M²: <1.5, Beam divergence, full angle (mrad): <3.0, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for UN-Ti-740-840; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

UN-Ti-740-840: 740 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

UN-Ti-740-840: 740 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

UN-Ti-740-840: 740 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Collimation

UN-Ti-740-840: Collimation benefits from a stable, focusable source. 740 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

System integration

Integration and compatibility

Use these checks to connect UN-Ti-740-840 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Beam / notes: Water cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for UN-Ti-740-840

What cooling does the UN-Ti-740-840 require?

Beam / notes: Water cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare UN-Ti-740-840 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterUN-Ti-740-840 (current)FC-740MDL-740(FC)
Wavelength740 nm740 nm740 nm
Optical power / pulse energy1~7000 mW1~5 W1~2000 mW
Operating mode / pulse widthConfirm for this modelConfirm for this modelConfirm for this model
Beam qualityConfirm for this modelConfirm for this modelConfirm for this model