Power stability, linewidth, beam quality

U-496-SF496 nm green CW laser

496 nm

U-496-SF is a 496 nm CW laser. Used for collimation, laser medical treatment, flow cytometry, dna sequencing. Laser. Key specifications: output / average power 1~100 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

U-496-SF

2 specification rows

Wavelength496 nm
Output / average power1~100 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~100 mW
  • Output / average power: 1~50 mW
  • Output / average power: 1~20 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state M²: ~3.0, M²: <2, <1.5, Beam divergence, full angle (mrad): ~1.0, and Beam divergence (mrad): <3.0. These are series context, not guaranteed values for U-496-SF; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Collimation

U-496-SF: Collimation benefits from a stable, focusable source. 496 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Laser medical treatment

U-496-SF: 496 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Flow cytometry

U-496-SF: 496 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

U-496-SF: 496 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare U-496-SF with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterU-496-SF (current)MBL-U-496-SFMLL-III-495L
Wavelength496 nm496 nm495 nm
Optical power / pulse energy1~100 mW1~100 mW1~50 mW
Operating mode / pulse widthConfirm for this modelConfirm for this modelCW
Beam qualityConfirm for this modelConfirm for this modelNear TEM00