Measurement
TEM-LN-852: Measurement benefits from a stable, focusable source. 852 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.5) informs waist size and propagation.
Power stability, linewidth, beam quality
TEM-LN-852 is a 852 nm CW laser. Used for measurement, communication, spectrum analysis. TEM 00. Key specifications: output / average power 1~350 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
19 specification rows
| Output / average power | 1~350 mW |
|---|---|
| Beam / notes | TEM 00 |
| Operating mode | CW |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1%, <0.5% |
| Noise of amplitude (rms, 20Hz-20MHz) | <1%, <0.5% |
| M2 | <1.1 |
| Beam divergence, full angle (mrad) | <1.5 |
| Warm-up time (minutes) | <5 |
| Operating temperature (°C) | 25±3 |
| Power supply (100-240VAC) | PSU-III-FDA/PSU-III-LED/PSU-A-D |
| Expected lifetime (hours) | >10000 |
| Central wavelength (nm) | 852±10 |
| Output power (mW) | 1-350 |
| Transverse mode | TEM00 |
| Ellipticity | >0.95 |
| M² | <1.1 |
| Beam diameter at the aperture (1/e2, mm) | ~1.0 |
| Beam height from base plate (mm) | 25 |
| Modulation option | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
TEM-LN-852: Measurement benefits from a stable, focusable source. 852 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.5) informs waist size and propagation.
TEM-LN-852: 852 nm emission must sit inside the fiber-component passband used for Communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.
TEM-LN-852: 852 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<1.5) also controls focusing and collection geometry.
System integration
Use these checks to connect TEM-LN-852 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 25±3. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
M2: <1.1 · Beam divergence, full angle (mrad): <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare TEM-LN-852 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | TEM-LN-852 (current) | MDL-852(FC) | FC-852 |
|---|---|---|---|
| Wavelength | 852 nm | 852 nm | 852 nm |
| Optical power / pulse energy | 1~350 mW | 1~1200 mW | 1~5 W |
| Operating mode / pulse width | CW | CW | Confirm for this model |
| Beam quality | <1.5 | <1.0 | Confirm for this model |
Compare the TEM-LN-852 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide