Back to Home

Power stability, linewidth, beam quality

PGL-VI-447447 nm violet CW laser

447 nm

PGL-VI-447 is a 447 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. PGL-VI-447/ 1~80mW. Key specifications: output / average power 1~80 mW, transverse mode Near TEM00, operating voltage(internal pcb1) 5VDC(TTL30kHz and Analog0-3V,0-5V, optional). View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-VI-447

10 specification rows

Wavelength447 nm
Output / average power1~80 mW
Beam / notesPGL-VI-447/ 1~80 mW
Transverse modeNear TEM00
Operating voltage(internal PCB1)5VDC(TTL30kHz and Analog0-3V,0-5V, optional)
ConnectionCable with flying leads
Operating temperature0°C to 40°C
Storage temperature-20°C to 80°C
Humidity<90%, non-condensing
Dimensions of internal PCB mmΦ12×50
Dimensions of internal PCB1 mmΦ15×90

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

PGL-VI-447: 447 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

PGL-VI-447: 447 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

PGL-VI-447: 447 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Spectrum analysis

PGL-VI-447: 447 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (Near TEM00) also controls focusing and collection geometry.

System integration

Integration and compatibility

Use these checks to connect PGL-VI-447 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: 0°C to 40°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of internal PCB mm: Φ12×50 · Dimensions of internal PCB1 mm: Φ15×90
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-VI-447

What cooling does the PGL-VI-447 require?

Operating temperature: 0°C to 40°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-VI-447 deliver?

Transverse mode: Near TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-VI-447 mounted?

Dimensions of internal PCB mm: Φ12×50 · Dimensions of internal PCB1 mm: Φ15×90. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-VI-447 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-VI-447 (current)MDL-447(FC)FC-447
Wavelength447 nm447 nm447 nm
Optical power / pulse energy1~80 mW1~15 W1~30 W
Operating mode / pulse widthConfirm for this modelCWConfirm for this model
Beam qualityNear TEM00<1Confirm for this model